Biomass Override

The model allows the user to specify a total biomass that the plant will produce each year. When the biomass override is set in the plant operation (.mgt), the impact of variation in growing conditions from year to year is ignored, i.e. γreg\gamma_{reg} is always set to 1.00 when biomass override is activated in an HRU.

When a value is defined for the biomass override, the change in biomass is calculated:

Δbioact=Δbioi(biotrgbioi1)biotrg\Delta bio_{act} = \Delta bio_i*\frac{(bio_{trg}-bio_{i-1})}{bio_{trg}} 5:3.2.4

where Δbioact\Delta bio_{act} is the actual increase in total plant biomass on day ii (kg/ha), Δbioi\Delta bio_i is the potential increase in total plant biomass on day ii calculated with equation 5:2.1.2 (kg/ha), biotrgbio_{trg} is the target biomass specified by the user (kg/ha), and bioi1bio_{i-1} is the total plant biomass accumulated on day i1i-1 (kg/ha).

Table 5:3-2: SWAT+ input variables that pertain to actual plant growth.

Variable NameDefinitionInput File

BIO_TARG

biotrg/1000bio_{trg}/1000: Biomass target (metric tons/ha)

.mgt