Actual Yield

The harvest index predicted with equation 5:2.4.1 is affected by water deficit using the relationship:

HIact=(HIHImin)γwuγwu+exp[6.130.883γwu]+HIminHI_{act}=(HI-HI_{min})*\frac{\gamma _{wu}}{\gamma _{wu}+exp[6.13-0.883*\gamma _{wu}]}+HI_{min} 5:3.3.1

where HIactHI_{act} is the actual harvest index, HIHI is the potential harvest index on the day of harvest calculated with equation 5:2.4.1, HIminHI_{min} is the harvest index for the plant in drought conditions and represents the minimum harvest index allowed for the plant, and γwu\gamma _{wu} is the water deficiency factor. The water deficiency factor is calculated:

γwu=100i=1mEai=1mEo\gamma_{wu}=100*\frac{\sum^m_{i=1} E_a}{\sum ^m_{i=1} E_o} 5:3.3.2

where EaE_a is the actual evapotranspiration on a given day, EoE_o is the potential evapotranspiration on a given day, ii is a day in the plant growing season, and mm is the day of harvest if the plant is harvested before it reaches maturity or the last day of the growing season if the plant is harvested after it reaches maturity.

Last updated