Slope Adjustments

The moisture condition II curve numbers provided in the tables are assumed to be appropriate for 5% slopes. Williams (1995) developed an equation to adjust the curve number to a different slope:

CN2s=(CN3CN2)3[12exp(13.86slp)]+CN2CN_{2s}=\frac{(CN_3-CN_2)}{3}*[1-2*exp(-13.86*slp)]+CN_2 2:1.1.12

where CN2sCN_{2s} is the moisture condition II curve number adjusted for slope, CN3CN_3 is the moisture condition III curve number for the default 5% slope, CN2CN_2 is the moisture condition II curve number for the default 5% slope, and slpslp is the average fraction slope of the subbasin. SWAT+ does not adjust curve numbers for slope. If the user wishes to adjust the curve numbers for slope effects, the adjustment must be done prior to entering the curve numbers in the management input file.

Table 2:1-1: SWAT+ input variables that pertain to surface runoff calculated with the SCS curve number method.

Variable NameDefinitionInput File

IEVENT

Rainfall, runoff, routing option.

.bsn

ICN

Daily curve number calculation method: 0 calculate daily CN value as a function of soil moisture; 1 calculate daily CN value as a function of plant evapotranspiration

.bsn

CNCOEF

cncoefcncoef: Weighting coefficient used to calculate the retention coefficient for daily curve number calculations dependent on plant evapotranspiration

.bsn

PRECIPITATION

RdayR_{day}: Daily precipitation (mm H2_2O)

.pcp

CN2

CN2CN_2: Moisture condition II curve number

.mgt

CNOP

CN2CN_2: Moisture condition II curve number

.mgt

Last updated