Measured Daily Outflow

When measured daily outflow (IRESCO = 3) is chosen as the method to calculate reservoir outflow, the user must provide a file with the outflow rate for every day the reservoir is simulated in the watershed. The volume of outflow from the reservoir is then calculated:

Vflowout=86400∗qoutV_{flowout}=86400*q_{out}Vflowout​=86400∗qout​ 8:1.1.8

where VflowoutV_{flowout}Vflowout​ is the volume of water flowing out of the water body during the day (m3^33 H2_22​O), and qoutq_{out}qout​ is the outflow rate (m3^33/s).