Pond outflow is calculated as a function of target storage. The target storage varies based on flood season and soil water content. The target pond volume is calculated:
if 8:1.2.11
if or 8:1.2.12
where is the target pond volume for a given day (m HO), is the volume of water held in the pond when filled to the emergency spillway (m HO), is the volume of water held in the pond when filled to the principal spillway (m HO), is the average soil water content in the subbasin (mm HO), is the water content of the subbasin soil at field capacity (mm HO), is the month of the year, is the beginning month of the flood season, and is the ending month of the flood season.
Once the target storage is defined, the outflow is calculated:
8:1.2.13
where is the volume of water flowing out of the water body during the day (m HO), is the volume of water stored in the pond (m HO), is the target pond volume for a given day (m HO), and is the number of days required for the pond to reach target storage.