Seepage

The volume of water lost by seepage through the bottom of the pothole on a given day is calculated as a function of the water content of the soil profile beneath the pothole.

Vseep=240∗Ksat∗SAV_{seep}=240*K_{sat}*SAVseep​=240∗Ksat​∗SA if SW<0.5∗FCSW<0.5*FCSW<0.5∗FC 8:1.3.7

Vseep=240∗(1−SWFC)∗Ksat∗SAV_{seep}=240*(1-\frac{SW}{FC})*K_{sat}*SAVseep​=240∗(1−FCSW​)∗Ksat​∗SA if 0.5∗FC≤SW<FC0.5*FC \le SW <FC0.5∗FC≤SW<FC 8:1.3.8

Vseep=0V_{seep}=0Vseep​=0 if SW≥FCSW \ge FCSW≥FC 8:1.3.9

where VseepV_{seep}Vseep​ is the volume of water lost from the water body by seepage (m3^33 H2_22​O), KsatK_{sat}Ksat​ is the effective saturated hydraulic conductivity of the 1st soil layer in the profile (mm/hr), is the surface area of the water body (ha), is the soil water content of the profile on a given day (mm HO), and is the field capacity soil water content (mm HO). Water lost from the pothole by seepage is added to the soil profile.

SASASA
SWSWSW
2_22​
FCFCFC
2_22​